Reporting Codes
A P P E N D I X A
The following tables contain Contact ID and Automatic SIA format
reporting codes.
Contact ID
The first digit (in parentheses) will automatically be sent by the
control. The second two digits are programmed to indicate
specific information about the signal.
For example, if zone 1 is an entry/exit point, you could program
the event code as [34]. The central station would receive the
following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the
level 2 specifications of the SIA Digital Communication
Standard - January 1996. This format will send the Account
Code along with its data transmission. The transmission would
look similar to the following at the receiver:
N Ri01 BA 01
N = New Event
Ri01 = Partition /Area Identifier
BA = Burglary Alarm
01 = Zone 1
Table 1 - Reporting Codes and Descriptions
Section
#
Reporting Code Code Sent When... Dialer
Direction*
Contact
ID Codes
SIA Auto Rep
Codes**
[320]
Zone Alarms zone goes into alarm A/R (1) 3A See
Table 3
[324]
Zone Restorals alarm condition has been restored A/R (1) 3A
[330]
[334]
Zone Tamper/Restoral zone exhibits a tamper condition/tamper condition restored T/R (1) 44 TA-ZZ/TR-ZZ
[328]
Duress Alarm duress code entered at keypad A/R (1) 21 HA-00
[328]
Opening After Alarm system disarmed with alarm in memory A/R (4) A6 OR-00
[328]
Recent Closing alarm occurs within two minutes of system arming A/R (4) 59 CR-00
[328]
Zone Expander Supervisory
Alarm/Rest.
panel loses/retores supervisory transmission over the keybus
from enrolled PC5132 module or keypads with zone inputs
A/R (1) 43 UA-00/UH-00
[328]
Cross Zone (Police Code)
Alarm
two zones on the same partition go into alarm during any given
armed-to-armed period (incl. 24Hr zones)
A/R (1) 4A BV-00
[329]
[F] Key Alarm/Rest. Keypad fire alarm (alarm and restore rep. codes sent together) A/R (1) 15 FA-00/FH-00
[329]
[A] Key Alarm/Rest. Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
A/R (1) AA MA-00/MH-00
[329]
[P] Key Alarm/Rest. Keypad panic alarm (alarm and restore rep. codes sent together) A/R (1) 2A PA-00/PH-00
[329]
PGM2 Alarm/Rest. a panic button wired to PGM2 is pressed / access code is
entered (PGM2 programmed as option [23] or [24])
A/R (1) 2A UA-99/UH-99
[338]
General System Tamper/Rest. enrolled module with tamper inputs has a tamper alarm/all
module tampers restored
T/R (1) 45 TA-00/TR-00
[338]
Keypad Lockout max. number of incorrect access codes has been entered at a
keypad
T/R (4) 21 JA-00
[339-343]
Closings system armed (user 01-34, 40-42 indicated) O/C (4) A2 CL-UU
[343]
Partial Closing one or more zones bypassed when system armed O/C (4) 7A CG-ZZ
[343]
Special Closing Closing (arming) using one of the following methods: quick
arm, auto arm, keyswitch, function key, maintenance code, DLS
software
O/C (4) AA CL-00
[344-348]
Openings system disarmed (user 01-34, 40-42 indicated) O/C (4) A2 OP-UU
[348]
Auto Arm Cancellation auto arm cancelled O/C (4) A5 CE-00
[348]
Special Opening Opening (disarming) using one of the following methods:
keyswitch, maintenance code, DLS software
O/C (4) AA OP-00
[349-350]
Battery Trouble/Rest. panel battery is low/battery restored MA/R (3) A2 YT-00/YR-00
* A/R = alarms/restorals;T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions