DSC Power608 Especificações

Consulte online ou descarregue Especificações para Sistemas de segurança - controlo de acesso DSC Power608. DSC Power608 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
1.1 Specifications
Downloading Software Support
PC5008 uses DLS-1 v6.5 and up.
Flexible Zone Configuration
Six fully programmable zones; system expandable to eight
zones using keypad zone inputs and wireless zones
38 access codes: one master code, one maintenance code,
two duress codes, two supervision codes and 32 general
access codes
27 zone types; 8 programmable zone attributes
Normally closed, single EOL and double EOL zone wiring
• Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
700mA Supervised Bell Output (current limited at 3 amps),
12VDC
Steady or Pulsed Output
EEPROM Memory
Does not lose programming or system status on complete AC
and Battery failure
Programmable Outputs
One programmable voltage output and one programmable
voltage output/input; 22 programmable options
PGM1 = 300mA; PGM2 = 50mA
Eight additional low current (50mA) outputs available using
the PC5208 module
Four additional high current (300mA) outputs available using
the PC5204 module; one PC5204 output fully supervised for
siren
Powerful 1.5 Amp Regulated Power Supply
550 mA Auxiliary Supply, 12 V
DC
Positive Temperature Coefficient (PTC) components replace
fuses
Supervision for loss of AC power, low battery
Internal clock locked to AC power frequency
Power Requirements
Transformer = 16.5 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
Two keypads available:
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
All keypads have five programmable function keys
Connect up to eight keypads
4-wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications
• Supports major communication formats including SIA and
Contact ID
Event-initiated personal paging
Three programmable telephone numbers
Two account numbers
Supports LINKS1000 cellular communication
Supports LINKS2X50 Long Range Radio Transmitter
DTMF and pulse dialing
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC5008 continuously monitors a number of possible trouble
conditions including:
AC power failure
Trouble by zone
Tamper by zone
Fire trouble
Telephone line trouble
Failure to communicate
Low battery condition
Bell output trouble
Module fault (supervisory or tamper)
Loss of internal clock
AUX Power Supply Trouble
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Communication Delay
Urgency on Entry Delay
Quick Exit
Cross Zone Burglary Alarm
Rotating Keypress Buffer
Additional Features
Auto Arm at specified time
Keypad-activated alarm output and communicator test
All modules connect to the system via a four wire Keybus up
to 1000’/330m from main panel
An event buffer which records the past 128 events with both
the time and date at which they occurred; buffer can be
printed using PC5400 serial interface module, or viewed with
the LCD5500Z keypad.
• Supports the addition of the PC5132 Wireless receiver for
integration of wireless devices
Uploading and downloading capability
Local downloading capability through the use of the PC-LINK
adaptor
Supports the Escort5580 Voice Prompt Module with
Automation/Lighting Control
Supports the addition of the PC5928 Audio Interface Module
to integrate intercom stations
Added Keybus fault protection: clock and data outputs have
been programmed to withstand shorts to +12v to prevent
control panel damage
System Introduction
S E C T I O N 1
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - System Introduction

11.1 SpecificationsDownloading Software Support• PC5008 uses DLS-1 v6.5 and up.Flexible Zone Configuration• Six fully programmable zones; system expan

Página 2 - 1.3 Out of the Box

KEYPADVCOMMANDS10[✱] [3] Alarm MemoryThe Memory (or System) light will be on if any alarm occurredduring the last armed period or – in the case of 24

Página 3 - Getting Started

KEYPADVCOMMANDS11Brightness ControlYou can select from 10 different backlighting levels. Use thearrow keys (< >) to scroll to the desired backli

Página 4 - Accessories

KEYPADVCOMMANDS12[14] [✱] [7] [2] Reset (Command Output Option #2): Asdescribed above.[15] General Voice Prompt Help: This feature can only beprogramm

Página 5 - 2.8 Zone Wiring

13How to ProgramSECTION4The following section of the manual describes the Installer’sProgramming function and how to program the various sections.You

Página 6 - 2.11 LINKS Zone Wiring

HOWVTOVPROGRAM144.4 Programming Toggle Option SectionsSome programming sections contain several toggle options.The panel will use zone lights 1 throug

Página 7 - 2.12 Keypad Zones

15Program DescriptionsThe following section explains the operation of all programmablefeatures and options and provides a summary of allcorresponding

Página 8 - Keypad Commands

P R O G R A M D E S C R I P T I O N S16A violated Fire zone will be displayed on all keypads and canbe delayed at any keypad. Typically this zone is

Página 9

P R O G R A M D E S C R I P T I O N S17• Transmission Delay Enable – This attribute determineswhether or not the panel will delay communicating the a

Página 10 - ✱] to toggle

P R O G R A M D E S C R I P T I O N S18to call the central station. If the option is disabled, the panel willonly attempt to call the Third telephone

Página 11 - 3.5 Function Keys

P R O G R A M D E S C R I P T I O N S19The restoral will not be transmitted until alldetectors indicate good battery conditions.Wireless Maintenance

Página 12 - KEYPADVCOMMANDS

SYSTEMVINTRODUCTION21.2 Additional DevicesIn addition to the information below, see the back cover for aDSC module compatibility table.PC5132 Wireless

Página 13 - How to Program

P R O G R A M D E S C R I P T I O N S20Additional Notes on Contact ID1. Account numbers must be four digits.2. All reporting codes must be two digits

Página 14 - 4.5 Viewing Programming

P R O G R A M D E S C R I P T I O N S21The panel will immediately go on line and begin downloading. Ifthe Call-Back option is enabled, the panel and

Página 15 - Program Descriptions

P R O G R A M D E S C R I P T I O N S22Program which trouble conditions will activate the output byselecting some or all of the following attributes:

Página 16 - 5.3 Zone Attributes

P R O G R A M D E S C R I P T I O N S23[24] Audible 24 Hour (PGM2 Only)A Panic button may be placed on the PGM2 Terminal for use asan Audible 24 Hour

Página 17 - 5.5 Communicator – Dialing

P R O G R A M D E S C R I P T I O N S24If you have selected the Land Line Test Transmis-sion in Minutes option, do not program the testtransmission c

Página 18

P R O G R A M D E S C R I P T I O N S25Closing Confirmation ... Section [381]: [4]Opening After Alarm Keypad Ringback

Página 19

P R O G R A M D E S C R I P T I O N S26If the Power Save Mode option is enabled the panel will blankall keypad lights including backlighting when AC

Página 20 - 5.10 Downloading

P R O G R A M D E S C R I P T I O N S275.27 Additional System ModulesThe following modules are programmed through the ModuleProgramming sections [801

Página 21 - 5.11 PGM Output Options

P R O G R A M D E S C R I P T I O N S283. The Fire Bell is Continuous option is disabled (section [014]:[8])4. The Transmission Delay is disabled, if

Página 22 - ✱] [7] [2]:

29Programming WorksheetsSystem Zone Label Zone Zone Attributes* Serial NumberZone Type 1 2 3 4 5 6 7 8 (Wireless)Zone 1 I__ _ _ _

Página 23 - 5.14 Test Transmission

3Getting StartedS E C T I O N 2The following sections provide a thorough description of how towire and configure devices and zones.2.1 Installation S

Página 24

30P R O G R A M M I N G W O R K S H E E T SKeypad Programming[000] Keypad Enrollment (Section 2.5 “Keypad Enrollment”)NOTE: This must be done at eac

Página 25 - 5.22 Keypad Blanking

31P R O G R A M M I N G W O R K S H E E T S[006] Installer’s Code (Section 4.1 “Installer Programming”)Default: 5008 I_______I_______I_______I______

Página 26 - 5.25 Keypad Tampers

32P R O G R A M M I N G W O R K S H E E T S[014] Second System Option CodeDefault Option ON OFF SectionOFFI________I 1 Arm / Disarm Bell Squawk enabl

Página 27

33P R O G R A M M I N G W O R K S H E E T S[030] Zone Loop Response OptionsDefault Option ON OFF SectionOFF I________I 1 Zone 1 is Fast Loop Response

Página 28

34P R O G R A M M I N G W O R K S H E E T SPGM Output Attributes(Section 5.11 “PGM Output Options”)Program only the following attributes for the PGM

Página 29 - Programming Worksheets

35P R O G R A M M I N G W O R K S H E E T S[160] Maximum Dialing Attempts to Each Telephone Number(Section 5.5 “Communicator Dialing”)Default: 008 I_

Página 30

36P R O G R A M M I N G W O R K S H E E T S[324] Alarm Restoral Reporting Codes, Zones 1-8(Section 5.8 “Communicator – Reporting Codes” and Appendix

Página 31

37P R O G R A M M I N G W O R K S H E E T S[341] Closing (Arming) Reporting Codes, Access Codes 17-24(Section 5.8 “Communicator – Reporting Codes” an

Página 32 - (Section 2.12 “Keypad Zones”)

38P R O G R A M M I N G W O R K S H E E T S[349] Maintenance Alarm Reporting Codes(Section 5.8 “Communicator – Reporting Codes” and Appendix A)I_____

Página 33

39P R O G R A M M I N G W O R K S H E E T S[363] Tamper/Restore Communicator Call Directions(Section 5.5 “Communicator – Dialing”)Default Option ON O

Página 34

G E T T I N G S T A R T E D4Programmable Output Terminals – PGM1 andPGM2Each PGM output is designed so that when activated by thepanel, the terminal

Página 35 - Keypad Zone Assignments

40P R O G R A M M I N G W O R K S H E E T S[371] Test Transmission Time of Day (Section 5.14 “Test Transmission”)NOTE: If the land line test transmis

Página 36

41P R O G R A M M I N G W O R K S H E E T S[403] Downloading Access Code(Section 5.10 “Downloading”)Default: 5008 I_______I_______I_______I_______I E

Página 37

42P R O G R A M M I N G W O R K S H E E T SModule Programming[801] PC5400 Printer Module ProgrammingPlease refer to your PC5400 Installation Manual f

Página 38

43Reporting CodesA P P E N D I X AThe following tables contain Contact ID and Automatic SIA formatreporting codes.Contact IDThe first digit (in paren

Página 39

44R E P O R T I N G C O D E STable 2Contact ID Zone Alarm/Restoral Event Codes(as per ADEMCO):Program any of these codes for zone alarms/restorals wh

Página 40

45Programming LCD KeypadsA P P E N D I X BIf you have an LCD5500Z Keypad, additional programming is required for proper operation. The following is a

Página 41

46P R O G R A M M M I N G L C D K E Y P A D S[61] Second User Display MaskDefault Option ON OFFOFFI_______I 1 Installer Programming prompt ON Instal

Página 42 - Special Installer Functions

47ASCII Characters032064 176240033225241034035036228244038230246039231040248041249042058234043059123044060124236045061093125253046062094126238047 0630

Página 43 - Reporting Codes

© 1998 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6Tel. (416) 665-8460 • Fax (416) 665-7498Printed in Canada

Página 44 - (as per ADEMCO):

• W A R N I N G •This manual contains information on limitations regarding product use and function and information on thelimitations as to liability

Página 45 - Programming LCD Keypads

G E T T I N G S T A R T E D5calculations. Connected devices must not exceed systemcapabilities during any possible operational mode.2.5 Keypad Assign

Página 46

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelvemonths from the date of purchase, the produc

Página 47 - I_______I 5-8 For Future Use

Table of ContentsiPC5008 Control Panel Wiring Diagram iiSection 1: System Introduction 11.1 Specifications ...

Página 48 - CHANGES FOR PC5008 v2.1

PC5008 Control Panel Wiring DiagramiiTMPC5008 CONTROL PANEL WIRING DIAGRAMIncorrect connections mayresult in fuse failure or improperoperation. Inspec

Página 49 - Installation

G E T T I N G S T A R T E D6This option should be selected if either NormallyClosed (NC) or Normally Open (NO) detectiondevices or contacts are being

Página 50 - WARNING Please Read Carefully

G E T T I N G S T A R T E D72.12 Keypad ZonesEach “z” keypad on the system has a zone input to which adevice - such as a door contact - can be connec

Página 51 - Table of Contents

8Keypad CommandsSECTION3Use any system keypad to enter commands and/or program thePC5008 security system. The LED keypad uses function andzone indicat

Página 52

KEYPADVCOMMANDS9[✱] [2] Trouble DisplayThe panel constantly monitors itself for several different troubleconditions. If a trouble condition is present

Comentários a estes Manuais

Sem comentários