DSC NT9005 V1.0 Especificações Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 30
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
50
Table2: Contact ID Zone Alarm/Restoral
Event Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals
when using the standard (non-automatic) Contact ID
reporting format.
Table 3: SIA Format Automatic Zone Alarm/
Restoral Codes
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. Module Failure
(1)13 Water Flow (1)44 Sensor Tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station (1)4A Cross Zone Police Code
(1)16 Duct 24 Hour Non-Burglary
(1)17 Flame (1)5A 24 Hour non-Burg
(1)18 Near Alarm (1)51 Gas Detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low Bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition
SIA Auto Rep
Codes*
Zone Alm/Rest.
Delay, Instant, Interior, Delay
Stay/Away, Interior Stay/Away,
24Hr Burg.
BA-ZZ/BH-ZZ
24Hr Supervisory Buzzer UA-ZZ/UH-ZZ
24Hr Sprinkler SA-ZZ/SH-ZZ
24Hr Gas GA-ZZ/GH-ZZ
24Hr Heat KA-ZZ/KH-ZZ
24Hr Medical MA-ZZ/MH-ZZ
24Hr Emergency (non-medical) QA-ZZ/QH-ZZ
24Hr Waterflow WA-ZZ/WH-ZZ
24Hr Freeze ZA-ZZ/ZH-ZZ
24Hr Holdup HA-ZZ/HH-ZZ
24Hr Panic PA-ZZ/PH-ZZ
Latching 24Hr BA-ZZ/BH-ZZ
* ZZ = zones 01-32
1-3 Modules and Devices
3
1-3 Modules and Devices
Refer to the relevant installation manuals for specifi-
cations, installation and operation of the following
modules and devices.
NT9204 Power Supply/Output Module
Provides 4 programmable 1.0 Ampere outputs
(PGMs) and Keybus interface for operation of;
LINKS2150, LINKS2450 Long Range Radio interfaces
and Skyroute cellemetry transmitter. Fully supervised
for tamper, AC trouble, low battery, and auxiliary
supply trouble.
WLS904P(L)-433 Wireless Motion Detector
Four detection patterns selectable with interchange-
able lenses. High traffic shutdown and adjustable
sensitivity. This device is fully supervised for tamper,
device fault, and low battery.
WLS906-433 Wireless Smoke Detector
Provides a 90º smoke detection pattern with auto-
matic self test and manual test button. Has a self-
contained 85 dB siren. This device is fully supervised
for tamper, device fault, low battery, low sensitivity.
WLS919-433 Wireless Key
Provides 4 programmable buttons for functions
such as Stay Arm, Away Arm, Disarm, Fire, Auxiliary
and Panic functions.
WLS912/(L)-433 Wireless Glassbreak Detector
Detects float, plate, tempered, wired, and laminated
glass breakage up to a distance of 20ft (6m). Do not
mount the detector closer than 3.3 ft/1m from the
protected glass. Sensitivity can be adjusted for spe-
cific environments and glass types. This device is
fully supervised for tamper, device fault, low battery,
low sensitivity.
WLS907T-433 Wireless Low Temperature Sensor
The low temperature sensor sends a signal when the
temperature of the premises falls below a pre-
defined temperature. This device is fully supervised
for tamper, device fault and low battery.
WLS925L-433 Mini Wireless Universal Transmitter
Low profile wireless transmitter - Can be used for
wireless door or window contact or terminal con-
nection for external contacts. This device is fully
supervised for tamper, device fault, low battery,
open and closed.
Skyroute®
The Skyroute transceiver communicates using the
control channel of an existing cellular network. It
can be used as the sole communicator or as backup
for land line communications. The NT9204 Power
Supply/Output Module is required to interface with
the the control panel.
DLS2002 Downloading Software
Enables the installer to program or monitor the sys-
tem with a computer, modem and telephone line or
locally using a computer and PC-Link.
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM