36
[338] Misc. Tamper Codes
These codes are sent to the Tamper Alarm and Restorals Call Direc-
tion Group programmed in section [363].
I_3_I_7_I General System Tamper
This code is sent when a tamper exists on the main panel or
a module. This code is sent in addition to the specific tamper.
I_3_I_7_I General System Tamper Restoral
I_2_I_1_I Keypad Lockout - This code is sent when the
system enters keypad lockout.
[339]-[347] Closing(Arming)/Opening Reporting Codes
These codes are sent to the Opening and Closing Call Direction
Group programmed in section [365].
Access Closing Opening
Code Section/Entry Section/Entry
01 [339] I_A_I_2_I [344] I_A_I_2_I
02 I_A_I_2_I I_A_I_2_I
03 I_A_I_2_I I_A_I_2_I
04 I_A_I_2_I I_A_I_2_I
05 I_A_I_2_I I_A_I_2_I
06 I_A_I_2_I I_A_I_2_I
07 I_A_I_2_I I_A_I_2_I
08 I_A_I_2_I I_A_I_2_I
09 [340] I_A_I_2_I [345] I_A_I_2_I
10 I_A_I_2_I I_A_I_2_I
11 I_A_I_2_I I_A_I_2_I
12 I_A_I_2_I I_A_I_2_I
13 I_A_I_2_I I_A_I_2_I
14 I_A_I_2_I I_A_I_2_I
15 I_A_I_2_I I_A_I_2_I
16 I_A_I_2_I I_A_I_2_I
17 [341] I_A_I_2_I [346] I_A_I_2_I
18 I_A_I_2_I I_A_I_2_I
19 I_A_I_2_I I_A_I_2_I
20 I_A_I_2_I I_A_I_2_I
21 I_A_I_2_I I_A_I_2_I
22 I_A_I_2_I I_A_I_2_I
23 I_A_I_2_I I_A_I_2_I
24 I_A_I_2_I I_A_I_2_I
25 [342] I_A_I_2_I [347] I_A_I_2_I
26 I_A_I_2_I I_A_I_2_I
27 I_A_I_2_I I_A_I_2_I
28 I_A_I_2_I I_A_I_2_I
29 I_A_I_2_I I_A_I_2_I
30 I_A_I_2_I I_A_I_2_I
31 I_A_I_2_I I_A_I_2_I
32 I_A_I_2_I I_A_I_2_I
3-3 [*] Functions
17
[*][7] Command Outputs [*][7][1-4]
See section [141] to [154] PGM Output Attributes. When
any of the four [*][7] outputs are activated, six acknowledg-
ment beeps are heard. These functions can be performed
when the system is armed or disarmed.
☞
When this command is executed, all outputs pro-
grammed as this type will be active. If multiple out-
puts are programmed as the same type, the PGM
options must be programmed the same.
1 Command Output #1 - This function is user-con-
trolled. This can be performed when a programma-
ble output is programmed as type [19]. This output
can be used for operating devices such as garage
door opener, special lighting or door strikes.
2 Command Output #2 - This function is user-con-
trolled. This function can be performed when a pro-
grammable output is programmed as type [20]. Type
[20] may be used for operating devices such as
garage door openers, special lighting or door strikes.
3 Command Output #3 - This function is user-con-
trolled. This function can be performed when a pro-
grammable output is programmed as type [21]. This
output can be used for operating devices such as
garage door opener, special lighting or door strikes.
4 Command Output #4 - This function is user-con-
trolled. This function can be performed when a pro-
grammable output is programmed as type [22]. This
output can be used for operating devices such as
garage door opener, special lighting or door strikes.
[*][8] Flash/Advanced Programming
Enter [*][8][Installer Code][1] to enter Flash Programming.
See Flash Programming for Details
Enter [*][8][Installer Code][2] to enter Advanced Program-
ming. See Chapter 5: Advanced Programming for Details
☞
The system must be disarmed to enter program-
ming.
[*][9] Arming without Entry Delay
When Disarmed, entering [*][9] or pressing a function key
programmed for No Entry Arm before entering an access code
arms the panel without any entry delay on the delay zones and
bypasses zones that are defined as Stay/Away. This command
is used to arm the system while at home. When the system is
armed in this mode, the Armed light will flash and the Bypass
light will be on to indicate the Stay/Away zones are
bypassed. Once the panel is armed in this mode, using [*][1]
will remove the bypass from the Stay/Away zones if they
were NOT manually bypassed. The [*][1] command used here
only removes the bypass from zones that have been automati-
cally bypassed with the [*][9] command.
When Armed, entering [*][9] will toggle the entry delay on
and off. This will function when armed in Stay or Away
modes, as well as when the system is [*][9] armed. If the
panel is already [*][9] armed and [*][9] is pressed, the Armed
light will stop flashing, and the panel will log Armed with
Entry. If [*][9] is pressed while armed in Stay or Away modes,
the Armed light will flash, and the panel will log Armed with
No Entry.