OFF Audible Exit Fault Disabled
For [*][9] arming, if Audible Exit fault is enabled, a vio-
lated zone will begin Entry Delay as indicated. If this
option is disabled, a violated delay zone at the end the
Exit Delay will cause an instant alarm.
7 ON Event Buffer follows Swinger Shut-
down
!
When an event reaches the swinger shutdown limit pro-
grammed in section [370], it will not log events to the
event buffer and communicate them to the central sta-
tion, until swinger shutdown is reset. This prevents the
panel from overwriting the buffer with useless events and
flooding the central station with calls.
The event buffer can be uploaded with DLS-3 software.
OFF Event Buffer logs Events past Shutdown
8 ON Temporal 3 Fire Signal Enabled
All fire bells will sound in the three temporal pattern
described in NFPA 72 (0.5 seconds ON, 0.5 seconds OFF,
0.5 seconds ON, 0.5 seconds OFF, 0.5seconds ON, 1.5
seconds OFF).
OFF Standard Pulsed Fire Signal !
All fire bells will sound with the standard 1 sec ON, 1 sec
OFF fire bell cadence.
Zone definitions [87], [88], and [F] key will use this if
enabled.
[014] Second System Option Codes
1 ON Bell Squawk on Arm/Disarm Enabled
The bell will sound a single squawk when armed in any man-
ner, and a double squawk upon disarming the system. If
there are alarms in memory, the bell will emit a series of three
squawk pairs to indicate the alarm memory.
OFF Bell Squawk on Arm/Disarm Disabled
!
The bell output will not squawk when the system is armed or
disarmed in any way.
2 ON Bell Squawk During Auto-arm Enabled
The bell output will sound a single squawk every 10 seconds
during the 1 minute Auto-arm pre-alert time.
OFF Bell Squawk During Auto-arm Disabled
!
The bell output will not be activated during the 1-minute
Auto-arm pre-alert time.
3 ON Bell Squawk On Exit Delay
The bell output will squawk once per second during the Exit
Delay time. The bell will also sound 3 squawks per second for
the final 10 seconds.
OFF No Bell Squawk On Exit Delay
!
This audible option does not apply to Stay and No Entry Arm-
ing Modes.
4 ON Bell Squawk On Entry Delay
The bell output will pulse with the same timing as the keypad
buzzer during the Entry Delay time.
OFF No Bell Squawk On Entry Delay
!
5 ON Bell Squawks On Trouble
Whenever there is a Trouble condition annunciated on the
system keypads, the bell will squawk 2 times every 10 sec-
onds (as per the keypad buzzer). The bell will be silenced
when the keypad beeps are silenced (any key pressed on key-
pad).
OFF No Bell Squawks On Trouble
!
6 ON Audible Exit With Urgency
!
The keypad will sound a pulsing tone (once per second) dur-
ing the Exit Delay. For the last 10 seconds of the Exit Delay,
the keypad and bell/siren (if enabled) will sound a different
tone (3 tones per second).
OFF Silent Exit Delay
7 ON Exit Delay Termination Enabled
The Exit Delay will be terminated when a Delay 1 Zone for the
entry/exit door or area is restored. Audible options associated
with the Exit Delay will be silenced when the Exit Delay is ter-
minated. Force-Armable Delay 1 type zones will also termi-
nate the Exit Delay.
OFF Exit Delay Termination Disabled
!
The Exit Delay timer will continue to count even after the
Delay Zone for the entry/exit door or area is restored. All
audible options associated with the Exit Delay will function
until the time programmed for the Exit Delay has elapsed.
8 ON Fire Bell is Continuous
For all Fire type alarms, the bell output will sound until an
access code is entered to silence the alarm or disarm the sys-
tem regardless of the time programmed for bell timeout in
section [005].
OFF Fire Bell follows Timeout
!
For all Fire type alarms, the bell output will sound for the
length of bell timeout or until an access code is entered.
[015] Third System Option Codes
1 ON [F] Key Enabled
!
Pressing and holding the [F] key for 2 seconds will generate a
Fire alarm. The keypad will sound a set of 3 beeps to
acknowledge the valid alarm and the bell or siren will sound
with a pulsing tone for the length of bell timeout. An alarm
reporting code (if programmed) will be transmitted.
If enabled, this key will generate alarms at all times.
OFF [F] Key Disabled
The [F] key will not sound or report an alarm when pressed.
2 ON [P] Key Audible (Bell/Beeps)
When a valid [P] key alarm is generated, the keypad buzzer
will sound a series of 3 beeps to acknowledge the alarm and
the bell or siren will sound for the length of bell timeout.
OFF [P] Key Silent
!
25
[
[
[005] System Times
Default
Entry Delay 1 030 I___I___I___I (000 - 255) seconds
Entry Delay 2 045 I___I___I___I (000 - 255) seconds
Exit Delay 060 I___I___I___I (000 - 255) seconds
Bell Cut-off 004 I___I___I___I (000 - 255) minutes
[006-008] Access Codes
All codes can be either 4 or 6 digits in length. The default is 4
digits. See section [701], option 5.
User codes and Duress codes are programmed via [*][5] pro-
gramming.
[006] Installer’s Code
Change value to prevent unauthorized access to system.
Default 5555 I___I___I___I___I___I___I
[007] Master Code
[*]
Function
The Master Code can perform any function. This code can be used
to program all access codes including the duress codes. If the Mas-
ter Code Not Changeable option in section [015][6] is enabled,
users will not be able to change the Master code.
Default 1234 I___I___I___I___I___I___I
[008] Maintenance Code
This is an Arm/Disarm only code. It cannot be used to activate [*][7]
outputs, program other user codes or enter the [*][6] menu. Open-
ings or closings using this code report as a Special Opening/Clos-
ing and will log to the event buffer as Maintenance Code.
Default AAAA I___I___I___I___I___I___I
[009-011] PGM Output Programming
PGM Outputs
1, 2
Programmed in section [009]. Attributes are
programmed in sections [141], [142]
PGM Outputs
11, 12, 13, 14
Programmed in section [011]. Attributes pro-
grammed in sections [151]-[154]
Unless indicated otherwise, attributes are as indicated below.
Attribute numbers not mentioned in the default section have
no impact on operation and are typically defaulted OFF.
Attribute Function
ON OFF
1
2
3
4
5
6-8
Enabled
Future Use
True Output
Output Pulsed
Code Required
Future Use
Disabled
Inverted Output
ON/OFF
No Code Required
01 Fire and Burglary Output - causes the PGM output to
switch to ground upon any bell activity. The output will be
pulsed or steady depending on the type of bell activity. The
output follows the time programmed for the bell time-out.
Default Attributes: 1,3 ON 2 OFF
See sections [005] option [4] and [014] option [8].
02-04 Not Used
05 Armed Status - The PGM output switches to ground when
the system is armed (beginning of the exit delay). The output
goes high (open) when the panel is disarmed.
Default Attributes: 1,3 ON 2,5 OFF
06 Ready to Arm - The PGM output switches to ground as long
as the system is Ready to Arm (all non force-armable zones
on the system are restored). Once an access code is entered
to arm the system and the exit delay begins, the PGM output
is deactivated.
Default Attributes: 1,3 ON 2 OFF
07 Keypad Buzzer Follow Mode - The PGM output will go low
when the keypad buzzer is activated by the events described
below. The PGM output will go low for as long as the keypad
buzzer is active.
- 24-Hr Supervisory Buzzer Zone
- Auto-arm Pre-alert (1 minute)
- Entry Delay
- Door Chime
Default Attributes: 1,3 ON 2 OFF
08 Courtesy Pulse - This option provides an output which fol-
lows the entry and exit times. It can be used to turn on a
courtesy light near the exit door for the duration of the entry/
exit times. Upon activation during an entry delay, the output
will remain active for 2 minutes past the entry or exit times to
allow enough time for complete and safe entry or exit to or
from the premises.
Default Attributes: 1,3 ON 2 OFF
09 System Trouble Output (with Trouble Options) - The
PGM output switches to ground when any of the selected
Troubles are detected on the system. The output will deacti-
vate when all of the selected Troubles are restored. The
attributes normally programmed in sections [141] to [154]
are replaced with the following options.
Default Attributes: ALL ON
Attribute Function
1
2
3
4
5
6
7
8
Service Required
A.C. Fail
Telephone Line Monitoring (TLM) Fault
Communications (Failure to Communicate)
Zone (Fire) Fault
Zone Tamper
Zone Low Battery
Loss of Clock
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM