p r o g r a m m i n g w o r k s h e e t s
Supervision
[81] Wireless supervisory Window
Default = 03
l
____
l
____
l
RF transmitter supervisory window (hours), valid entries are 01-12.
Panic Transmitters are NOT supervised and must be disabled in the following sections.
[82] Zone Transmitter Supervision Options (1-8)
Default = ON Option ON Option OFF
l
________
l
Option 1 Zone 01 Supervision enabled Disabled
l
________
l
Option 2 Zone 02 Supervision enabled Disabled
l
________
l
Option 3 Zone 03 Supervision enabled Disabled
l
________
l
Option 4 Zone 04 Supervision enabled Disabled
l
________
l
Option 5 Zone 05 Supervision enabled Disabled
l
________
l
Option 6 Zone 06 Supervision enabled Disabled
l
________
l
Option 7 Zone 07 Supervision enabled Disabled
l
________
l
Option 8 Zone 08 Supervision enabled Disabled
Special Installer Functions
[904] Wireless Device Placement Test
(Section 3.4 “Module Placement Test”)
• Select the device to be tested (Zones 01-08).
• Press [#] to Cancel.
Placement Control Unit Lights Sounder
Good Light 1 ON Steady 1 Beep
Fair Light 2 ON Steady 2 Beeps
Bad Light 3 ON Steady 3 Beeps
[990] Installer Lockout Enable
[991] Installer Lockout Disable