6.5 Transmission Delay
If Transmission Delay is being used, the Opening After Alarm code must be programmed. See
Section 4.4 “Reporting Codes”
If the transmission delay zone attribute is selected for a given zone, the panel will delay reporting an alarm for
that zone for the number of seconds programmed for the Transmission Delay Time. If the panel is disarmed
before the delay time expires, the panel will not report the event.
Transmission Delay Times.............................................................. Section [370]
6.6 Arming /Disarming Options
If the Quick Arm option is enabled, the panel can be armed without a user code by entering []
[0] or by
pressing the Stay or Away function key.
The Quick Exit option, if enabled, will allow someone to leave an armed premises through a Delay type zone
without having to disarm and rearm the system.
If the Arm/Disarm Bell Squawk option is enabled, the panel will squawk the alarm output once upon arming
and twice upon disarming. The Opening After Alarm Keypad Ringback option will give you the ability to
beep the keypad 10 times rapidly if the panel is disarmed after an alarm occurred. The Opening After Alarm
Bell Squawk
option will give you the ability to squawk the bell output 10 times rapidly if the panel is disarmed
after an alarm occurred.
Closing Confirmation, if enabled, will cause the keypad to beep 10 times rapidly after the closing Reporting
Code has been transmitted to central station.
If the Bypass Status Displayed While Armed is chosen, the System light will be ON while the system is
armed to indicate any bypassed zones.
To prevent false alarms on exit, use the built-in feature Audible Exit Fault. A fault will be indicated when the
user has failed to secure the system once they have exited the premises (see the WLS920 Instruction Manual
for a full description of this feature).
Quick Arm Enable.........................................................Section [015], Option [4]
Quick Exit Enable .........................................................Section [015], Option [3]
Arm/Disarm Bell Squawk .............................................Section [014], Option [1]
Closing Confirmation ....................................................Section [381], Option [4]
Opening After Alarm Keypad Ringback .......................Section [381], Option [1]
Opening After Alarm Bell Ringback .............................Section [381], Option [2]
Bypass Status Displayed While Armed........................Section [016], Option [7]
6.7 Entry/Exit Delay Options
Two different entrydelays can be programmed: the first entry delay will be enabled for Delay 1 type zones and
the second for Delay 2 type zones. Only one exit delay can be programmed.
Since two Delay zones – and therefore two different Entry Delays – are programmable, when the
panel is armed, the Entry Delay will begin when the first delay zone violated.
Upon arming, the panel will begin the exit delay. If the Audible Exit Delay with Urgency option is enabled,
the control unit will beep at one second intervals until the exit delay expires. The control unit will beep rapidly
for the last 10 seconds of exit delay to warn the user that the system is about to arm.
The Audible Exit Fault will notify the user if they failed to secure the premises upon arming.
For commercial applications, the Bell Squawk on Exit Delay option may be enabled. The panel will squawk
the alarm output once every second when the exit delay is initiated and three times per second for the last 10
seconds until the exit delay expires.
Upon entry, if a Delay type zone is violated, the panel will begin the entry delay. The control unit will emit a
steady tone. The control unit will pulse the sounder during the last 10 seconds to warn the user the system is
about to go into alarm. If there was an alarm during the armed period, the control unit will pulse for the entire
entry delay to warn the user of the previous alarm.
For commercial applications Bell Squawk on Entry Delay may be enabled. The panel will squawk the alarm
output once every second until the entry delay expires or the system is disarmed.
If the Bell Squawk During Auto Arm option is enabled, the bell will squawk when the system is auto-armed in
order to notify anyone on the premises that the system is being armed.
If the Exit Delay Termination option is enabled, the panel will monitor the Delay zones during exit delay.
During the exit delay, if a Delay type zone is violated and then secured, the exit delay will be terminated and
the panel will be armed immediately.