22
p r o g r a m m i n g w o r k s h e e t s
[360] Communicator Format Options
(Section 4.5 “Reporting Formats”)
The Third telephone number follows the format of the First telephone number.
Default
02
I_______I_______I 1st Phone Number
02
I_______I_______I 2nd Phone Number
01 20 BPS, 1400 HZ handshake 04 SIA FSK
02 20 BPS, 2300 HZ handshake 05 Pager
03 DTMF CONTACT ID
[361] Alarm/Restore Communicator Call Directions
(Section 4.1 “Dialing”)
Default Option ON OFF
ON I_______I 1 1st Telephone Number Disabled
OFF I_______I 2 2nd Telephone Number Disabled
[363] Tamper/Restore Communicator Call Directions
(Section 4.1 “Dialing”)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
[365] Opening/Closing Communicator Call Directions
(Section 4.1 “Dialing”)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
[367] System Maintenance Alarm/Restore Communicator Call Directions
(Section 4.1 “Dialing”)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF
I________I 2 2nd Telephone Number Disabled
[368] System Test Transmissions Communicator Call Directions
(Section 4.1 “Dialing”)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF
I________I 2 2nd Telephone Number Disabled
[370] Communication Variables
Default Section
003 I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled) 6.9
003 I_______I_______I_______I Swinger Shutdown (Tampers and Rest) (001-014 Transmissions, 000=disabled) 6.9
003
I_______I_______I_______I Swinger Shutdown (Maint and Rest) (001-014 Transmissions, 000=disabled) 6.9
000 I_______I_______I_______I Transmission Delay (001-255 seconds) 6.5
030 I_______I_______I_______I AC Failure Communication Delay (001-255 minutes) 4.4
003
I_______I_______I_______I TLM Trouble Delay
(No. of valid checks required +3 - 000-255 x 10s) 6.2
030 I_______I_______I_______I Test Transmission Cycle (land line) (001-255 days) 6.4
007 I_______I_______I_______I Zone Low Battery Transmission Delay (000-255 days) 4.4
NOTE: For AC failure communications delay 000 = Disabled.