MONITORING
This system is capable of transmitting alarms, troubles, and emergency information
over telephone lines to a monitoring station. If you inadvertently initiate an alarm,
immediately call the monitoring station to prevent an unnecessary response.
NOTE
: The monitoring function must be enabled by the installer before it becomes
functional.
GENERAL SYSTEM OPERATION
Your security system is made up of a PC4000 and one or more LCD-4500 and various
detectors and sensors. The DSC control panel will be mounted out of the way in a
utility room or basement. The metal cabinet contains the system electronics, fuses
and stand-by battery. There is normally no reason for anyone but the installer or
service person to have access to the control panel. The LCD-4500 keypads have an
audible indicator, an alphanumeric LCD, (Liquid Crystal Display), and command entry
keys. The keypad is used to send commands to the system and to display the current
system status. The keypad(s) will be mounted in convenient locations inside the
protected premises close to the exit-entry doors.
The security system has several zones or areas of protection and each of these
zones will have one or more detection sensors connected to it (motion detectors,
glassbreak detectors, door contacts or shock sensors). When a sensor is in alarm,
the zone in alarm will be displayed on the LCD-4500.
TROUBLE AND ARMED LED DISPLAYS
The LCD-4500 has a yellow LED on the right side of the keypad which represents
the trouble status of the panel. There is a red LED just below the yellow one which
represents the armed status of the panel.
SYSTEM MASTER CODES
System Master Codes are used for arming and disarming the control panel, for
viewing the armed/disarmed status of the partitions, for programming additional
security codes and for entering ‘user functions’. See [✱][5] User Programming
Commands for programming System Master Codes. In the disarmed state, entering a
Master Code will cause a nine selection menu to be displayed as follows:
[0]Arm Partition [1]Arm Diff Part. [2]Disarm Diff Part
[3]View Partitions [4]Set System Time [5]Set System Date
[6]System Reset [7]Enable DLS Window [8]Previous Menu
[0] Arm Partition will arm the partition the keypad is on. The keypad will display the
message ‘Exit delay in progress’ and the armed light will come on.
[1] Arm Diff Part. will show a menu of the other partitions and their armed/disarmed
status. R means it is ready to be armed, N means it is not ready to be armed,
and A means the partition is armed. If the partition status is R, then this partition
can be selected to be armed. If a partition is not enabled, it will not be displayed.
MAINTENANCE
With normal use, the system requires minimum maintenance. The following points
should be observed.
1.Do not wash the keypad with a wet cloth. Light dusting with a barely damp cloth
should remove normal accumulations of dust.
2.The battery/bell test is designed to determine battery condition, however it is
recommended that the stand-by batteries be replaced every three years.
3.For other system devices such as smoke detectors, passive infrared, ultrasonic or
microwave motion detectors or glassbreak detectors, consult the respective
manufacturer’s literature for testing and maintenance.
LIMITED WARRANTY
Digital Security Controls Ltd. warrants that for a period of twelve months from the
date of purchase, the product shall be free of defects in materials and workmanship
under normal use and that in fulfillment of any breach of such warranty, Digital
Security Controls Ltd. shall, at its option, repair or replace the defective equipment
upon return of the equipment to its factory. This warranty applies only to defects in
parts and workmanship and not to damage incurred in shipping or handling, or
damage due to causes beyond the control of Digital Security Controls Ltd. such as
lightning, excessive voltage, mechanical shock, water damage, or damage arising
out of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in
lieu of any and all other warranties, whether expressed or implied and of all other
obligations or liabilities on the part of Digital Security Controls Ltd. This warranty
contains the entire warranty. Digital Security Controls Ltd. neither assumes, nor
authorizes any other person purporting to act on its behalf to modify or to change this
warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct or indirect or
consequential damages, loss of anticipated profits, loss of time or any other losses
incurred by the buyer in connection with the purchase, installation or operation or
failure of this product.
WARNING
Digital Security Controls Ltd. recommends that the entire system be completely
tested on a regular basis. However, despite frequent testing, and due to, but not
limited to, criminal tampering or electrical disruption, it is possible for this product to
fail to perform as expected.
15