
43
DELETE AREADELETE AREA
DELETE AREADELETE AREA
DELETE AREA
(1)(1)
(1)(1)
(1)
COPY AREACOPY AREA
COPY AREACOPY AREA
COPY AREA
(2)(2)
(2)(2)
(2)
YES = The reporting of zone alarm will be delayed for the programmed time. If the system is
disarmed within this time, no alarm signal will be communicated. (See “Zone TX Delay”.)
NO = When an alarm occurs, the reporting code is transmitted immediately.
Alarm and Seismic Groups
You can assign multiple zones to one or more alarm groups (01-32). When a zone in an alarm group goes
into alarm, outputs programmed for the alarm group will be triggered. This allows you to program zones to
trigger outputs independently of their area assignments.
For this to work, you must assign the zone(s) to one or more groups in this section, and program the PGM
output for an alarm group (see “Programmable Output Options - Alarm Groups”).
In order for zones to be included in a Seismic Test, you need to assign each one to a seismic group (01-32).
Assign each zone to the same seismic group as the Seismic Pulse output that will test it. See “Programmable
Output Options - Seismic Pulse” for more information.
Area Label
Program a label for the area. See “Zone Label” programming for instructions.
NOTE: The maximum length of the area name label is 14 characters.
Delete/Copy Area
Disables an area.
If an area is deleted, the system will not erase any programming. If you decide to re-enable the area, the
programming will still be there. Only the zones will have to be assigned.
To delete an area, you must delete all zones that are assigned to the area. When selecting the Delete area
option, only areas that have no zones assigned to them will be displayed. If the Delete Area option is
selected, and there are no areas that are ready to be deleted, the message “No Areas Are Available” will be
displayed for three seconds.
Copies an area.
Copies the programming from one area to another one. This includes the Area ID Code, Area Toggles, and
the Area Times. The zone assignment is not copied.
Only areas that are active may be copied to other areas. To select an area to copy, the area must first be
active on the system. Once the area is selected it may only be copied to an area which is not currently active
on the system. If there are no areas that are not active, the message “No Areas Are Available” will be
displayed for three seconds.
ALARM GROUPSALARM GROUPS
ALARM GROUPSALARM GROUPS
ALARM GROUPS
(3)(3)
(3)(3)
(3)
SEISMIC GROUPSSEISMIC GROUPS
SEISMIC GROUPSSEISMIC GROUPS
SEISMIC GROUPS
(5)(5)
(5)(5)
(5)
AREA SECTIONAREA SECTION
AREA SECTIONAREA SECTION
AREA SECTION
ADAD
ADAD
AD
D/D/
D/D/
D/
EDIT AREA EDIT AREA
EDIT AREA EDIT AREA
EDIT AREA
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT
ALARM/SEISMIC GROUPSALARM/SEISMIC GROUPS
ALARM/SEISMIC GROUPSALARM/SEISMIC GROUPS
ALARM/SEISMIC GROUPS
AREA LABELAREA LABEL
AREA LABELAREA LABEL
AREA LABEL
(4)(4)
(4)(4)
(4)
TX DELAY ?TX DELAY ?
TX DELAY ?TX DELAY ?
TX DELAY ?
NN
NN
N
Comentários a estes Manuais