42
A 24 Hour Medical zone is armed at all times, and will create an alarm when violated if the Area is armed
or disarmed.
When armed, if violated, this zone type will generate an audible alarm on the area the zone is assigned to.
To have seismic zones tested during a Seismic Test, assign the zones to a seismic group (see “Seismic
Groups”). You should assign the zones to the same seismic group as the Seismic Pulse outputs that will
test them (see “Programmable Output Options - Seismic Pulse”).
NOTE: Seismic zones will log a Seismic Fault for physical faults (i.e. if the zone is shorted or opened).
“Links Supervisory” is used with the LINKS1000 cellular communications unit to monitor for LINKS1000
troubles. When the Links PGM output activates, a Links trouble will be logged on the event buffer and the
zone trouble transmitted.
NOTE: Do NOT use the Double EOL resistors with this zone type.
This zone type provides the LINKS1000 with a forced answer for downloading purposes.
NOTE: Do NOT use the Double EOL resistors with this zone type.
Zone Options
Enabling or disabling options by zone.
NOTE: Every time a new zone type is selected, the zone options for the selected zone will be set to a
default setting. The default setting will be different depending on the zone type selected. The defaults
for each zone type are shown below.
Zone Attribute Defaults (Y = Option ON; N = Option OFF):
Attribute:
ON Audible Steady Bypass Chime Tx. Delay
OFF Silent Pulsed No No No
Zone Type:
00 Standard Delay Y N Y Y N
01 Force Delay Y N Y N N
02 Aux. Delay Y N Y Y N
03 Instant Y N Y Y N
04 Interior Y N Y N N
05 24Hr Bell Y N Y N N
06 24Hr Bell/Buzz. Y N Y N N
07 24Hr Buzz. Y N Y N N
08 Stand. Fire Y Y Y N N
09 Auto Verify Fire Y Y Y N N
10 Momentary Arm Y N Y N N
11 Maintained Arm Y N Y N N
12 24hr Holdup N N Y N N
13 Auxiliary Y N Y N N
14 24hr Auxiliary Y N Y N N
15 24hr Medical Y N Y N N
16 Seismic Y N Y N N
17 LINKS Supervisory N N Y N N
18 LINKS Answer N N Y N N
YES = An alarm causes the bell output to activate.
NO = Silent alarm.
YES = The bell output will pulse when the zone is in alarm.
NO = The bell output will be steady when the zone is in alarm.
YES = The zone may be manually bypassed.
NO = The zone cannot be bypassed.
YES = Every keypad on the area will chime both when the zone is violated and when the
zone is then secured. The area must be disarmed for the chime option to function.
NO = The zone will not chime the keypads.
ZONE OPTIONSZONE OPTIONS
ZONE OPTIONSZONE OPTIONS
ZONE OPTIONS
(2)(2)
(2)(2)
(2)
BELL AUDIBLEBELL AUDIBLE
BELL AUDIBLEBELL AUDIBLE
BELL AUDIBLE
YY
YY
Y
BELL PULSEDBELL PULSED
BELL PULSEDBELL PULSED
BELL PULSED
NN
NN
N
BYPASS ENABLEDBYPASS ENABLED
BYPASS ENABLEDBYPASS ENABLED
BYPASS ENABLED
YY
YY
Y
CHIME FUNCTIONCHIME FUNCTION
CHIME FUNCTIONCHIME FUNCTION
CHIME FUNCTION
YY
YY
Y
24HR MEDICAL24HR MEDICAL
24HR MEDICAL24HR MEDICAL
24HR MEDICAL
(15)(15)
(15)(15)
(15)
SEISMICSEISMIC
SEISMICSEISMIC
SEISMIC
(16)(16)
(16)(16)
(16)
AREA SECTIONAREA SECTION
AREA SECTIONAREA SECTION
AREA SECTION
ADD/EDIT AREA ADD/EDIT AREA
ADD/EDIT AREA ADD/EDIT AREA
ADD/EDIT AREA
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT
ZONE TYPEZONE TYPE
ZONE TYPEZONE TYPE
ZONE TYPE
AREA SECTIONAREA SECTION
AREA SECTIONAREA SECTION
AREA SECTION
ADD/EDIT AREA ADD/EDIT AREA
ADD/EDIT AREA ADD/EDIT AREA
ADD/EDIT AREA
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT ZONE ASSIGNMENT
ZONE ASSIGNMENT
ZONE OPTIONSZONE OPTIONS
ZONE OPTIONSZONE OPTIONS
ZONE OPTIONS
LINKS SUPERVISORYLINKS SUPERVISORY
LINKS SUPERVISORYLINKS SUPERVISORY
LINKS SUPERVISORY
(17)(17)
(17)(17)
(17)
LINKS ANSWERLINKS ANSWER
LINKS ANSWERLINKS ANSWER
LINKS ANSWER
(18)(18)
(18)(18)
(18)