DSC PC5020 Manual de Instalação Página 1

Consulte online ou descarregue Manual de Instalação para Sistemas de segurança - controlo de acesso DSC PC5020. DSC PC5020 Installation manual [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 43
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Installation
Manual
WARNING
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
PC5020 Version 3.0
DLS-3 v1.2 and higher
Vista de página 0
1 2 3 4 5 6 ... 42 43

Resumo do Conteúdo

Página 1 - Installation

Installation ManualWARNINGThis manual contains information on limitations regarding product use and function and information on the limitations as to

Página 2 - Table of Contents

Installation and Wiring: 2.5 Assigning Zones to Zone Expanders7System Outputs (all 12 VDC)PC5020 Device Ratings (@ 12 VDC)• LCD5500 Keypad: 50 mA• PC5

Página 3 - PC5020 Wiring Diagram

82.6 Keypad AssignmentThere are 8 available slots for keypads. LED and LCD5501Z key-pads by default are assigned to slot 1. The LCD5500Z is assigned b

Página 4 - Section 1: Introduction

Installation and Wiring: 2.9 Zone Wiring9for the panel (section [013], options [1] and [2]). See 5.1 “Zone Definitions”.If you change the zone supervi

Página 5 - 1.4 Additional Devices

10LINKS1000 AnswerIf the LINKS1000 cellular communicator is being used a zone may be configured for LINKS1000 Answer to allow downloading to be perfor

Página 6

11Section 3: How to ProgramThe following section of the manual describes how to enter Installer Programming and how to program the various sections.NO

Página 7 - 1.5 Out of the Box

123.5 Viewing ProgrammingLED and LCD5501Z KeypadsAny programming section can be viewed from an LED or LCD5501Z keypad. When a programming section is e

Página 8 - 2.2 Terminal Descriptions

13Section 4: Keypad CommandsUse any system keypad to enter commands, or to program the Power864 security system. The LED keypad uses function and zone

Página 9 - Accessories

14programmed through the [*][5] command, as described previ-ously in this section. The master code can also be programmed by the user as access code (

Página 10

Keypad Commands: 4.3 [*] Commands154.3 [*] Commands[*][1] Zone BypassingUsers can bypass individual zones using the [*] [1] keypad com-mand. This comm

Página 11 - 2.9 Zone Wiring

16[*] [3] Alarm MemoryThe ‘Memory’ light will be on if any alarm occurred during the last armed period or if an alarm occurred while the panel was dis

Página 12

iTable of ContentsSection 1: Introduction 11.1 About the Power864 System ... 11.2 About the Power864 Manual Set

Página 13 - 2.10 Keypad Zones

Keypad Commands: 4.4 Function Keys17options. Use the arrow keys (<>) to scroll to the desired back-light level and press the [#] key to exit.• C

Página 14 - Section 3: How to Program

18[05] - [*]+[9] No-Entry Delay ArmAfter this function key is pressed the user must enter a valid access code. The Partition will arm and remove entry

Página 15 - 3.5 Viewing Programming

Keypad Commands: 4.5 Global and Partition Keypad Operation19holding the [#] key, then pressing and holding the [3] key to select Partition 3 (see sect

Página 16 - Section 4: Keypad Commands

20Section 5: Programming SectionsThe following section explains all the programmable features including how the feature operates, options that pertain

Página 17 - 4.2 Arming and Disarming

Programming Sections: 5.2 Zone Attributes21[10] 24 Hour Supervisory Buzzer Zone: Whether armed or disarmed, when this zone type is violated the pane

Página 18 - 4.3 [*] Commands

22NOTE:The wireless zone attribute must be enabled for all enrolled wireless zones. Zones 1 to 64 Attributes . . . . . . . . . . . . . . Section [101]

Página 19

Programming Sections: 5.6 Communicator - Account Codes23If Alternate Dial is enabled the panel will alternate between the 1st and 3rd telephone number

Página 20 - 4.4 Function Keys

24NOTE: The zone number for Zone Low Battery and Zone Fault events will not be identified when Programmed Con-tact ID is used.If the Contact ID uses A

Página 21

Programming Sections: 5.8 Communicator - Reporting Codes25to communicate trouble will only be generated once the maxi-mum number of attempts has been

Página 22 - “[*][2] Trouble Display”

26A Bell Circuit Trouble Alarm Reporting Code will be transmit-ted immediately if an open condition is measured on the Bell Output of the main panel.

Página 23 - 5.1 Zone Definitions

iiPC5020 Wiring Diagram

Página 24 - 5.2 Zone Attributes

Programming Sections: 5.10 Telephone Line Monitoring (TLM)27assigned to slot 8. In addition, version 1.0 and version 2.0 LCD keypads are not compatibl

Página 25 - 5.4 Communicator - Dialing

28• 24 Hour Supervisory Buzzer Zone [08] Courtesy Pulse: Upon arming the output will activate for the duration of the exit delay plus two minutes.

Página 26

Programming Sections: 5.13 Bell Options29PGM output options [01], [03], [05]-[08], [11]-[22] have the fol-lowing attributes:PGM attributes return to t

Página 27

30Alarm Bell Squawk option is turned on, the system will squawk the bell output 10 times rapidly if the panel is disarmed after an alarm occurred.Clos

Página 28 - DC. The Bat

Programming Sections: 5.18 Event Buffer31For commercial applications Bell Squawk on Exit Delay may be enabled. The panel will squawk the alarm output

Página 29 - 5.9 Downloading

32If the Power Save Option is enabled the panel will blank all keypad lights including backlighting when AC power fails, in order to conserve the back

Página 30 - 5.12 Programmable Outputs

Programming Sections: 5.25 Module Programming33The LINKS1000 Special Preamble is sent BEFORE the Preamble programmed in Sections [390] to [392].Exampl

Página 31

34Restore PC5132 to Factory Default Programming .Section [996]Restore PC5400 to Factory Default Programming .Section [997]Restore PC5928 to Factory De

Página 32 - 5.13 Bell Options

35Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA for-mat reporting codes. For more information on reporting code

Página 33 - 5.16 Automatic Arming

36Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when using the standard (non

Página 34 - 5.20 Keypad Options

1Section 1: Introduction1.1 About the Power864 SystemThe Power864 is a high end security system. It supports up to 64 zones, 8 separate partitions, an

Página 36 - 5.26 Factory Default

38FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digi-tal Security Controls Ltd. could void your authority to use

Página 37 - 5.28 Walk Test

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system use

Página 38 - Appendix A: Reporting Codes

©1999 Digital Security Controls Ltd., Toronto, Canadawww.dscgrp.com Printed in Canada 29003974 R002PC5020 Module CompatibilityModule Compatible? Comm

Página 39 - Alarm/Restoral Codes

2Digital Communicator Specifications:• Supports all major formats including SIA, Contact ID, and Res-idential Dial• Split reporting of selected transm

Página 40

Introduction: 1.4 Additional Devices3WLS907 Wireless Universal TransmitterThe Wireless Slimline Universal Transmitter can be used with the PC5132 Wire

Página 41

4NOTE: The PC5700 and PC5720 each enroll as two expander modules and use up two supervisory slots. NOTE: Do not mix PC5700 and PC5720 v1.x and lower m

Página 42 - Limited Warranty

5Section 2: Installation and WiringThe following sections provide a complete description of how to wire and configure devices and zones.2.1 Installati

Página 43 - PC5020 Module Compatibility

6has four Keybus terminals that must be connected to the four Keybus terminals on the panel. For more information, see section 2.3 “Keybus Operation a

Comentários a estes Manuais

Sem comentários