38
KEYPAD HOOKUP
1. Each keypad has four colored leads: red (RED), black (BLK), yellow (YEL), and green (GRN). Connect the leads to
the corresponding terminals on the panel.
2. Up to 3 keypads may be connected in parallel. DO NOT connect multiple keypads on the same loop.
3. The wiring table gives the maximum wire run for various gauges of wire. Wire run lenghts are calculated on the
maximum current drawn by the keypad (when all lights are ON).
4. For stand-by loading purposes, it is recommended that a current draw of 20 mA per keypad be used. This represents
the panel in a disarmed state with two zones in alarm.
Note: If two wires of the same gauge are paralleled, the run length can be doubled. For example, If eight 22AWG
wires (2 RED, 2 BLK, 2 YEL, 2 GRN) are run to the keypad, the run length would double from 540 feet (164.5 m) to
1080 feet (329 m).
FIRE CIRCUIT HOOKUP
Smoke Detector Power Loop Wiring Chart
Loop
Current
mA
AWG14 AWG16 AWG18 AWG19 AWG22
Maximum wire run to EOL relay in feet / meters
50 2750 / 8381740 / 5301090 / 332 869 / 264 433 / 131
100 1375 / 419 870 / 265 545 / 166 434 / 132 216 / 66
200 690 / 210 435 / 132 270 / 82 217 / 66 108 / 33
300 460 / 140 290 / 88 180 / 55 144 / 43 144 / 43
400 345 / 105 215 / 65 135 / 41 108 / 33 54 / 16
Bell Loop Wiring Chart
Bell
Current
mA
AWG14 AWG16 AWG18 AWG19 AWG22
Maximum wire run to EOL resistor in feet / meters
50 2750 / 838 1740 / 530 1090 / 332 869 / 264 433 / 131
100 1375 / 419 870 / 265 545 / 166 434 / 132 216 / 66
200 690 / 210 435 / 132 270 / 82 217 / 66 108 / 33
300 460 / 140 290 / 88 180 / 55 144 / 43 144 / 43
400 345 / 105 215 / 65 135 / 41 108 / 33 54 / 16
500 275 / 83 170 / 52 105 / 32 86 / 26 43 / 13
600 230 / 59 140 / 43 90 / 27 72 / 22 36 / 11
700 195 / 59 125 / 38 80 / 24 62 / 19 30 / 9
Alarm Initiating Loop
Wiring Chart
Wire
Gauge
Max. Run to
EOL Resistor
14AWG 15500' / 4724m
16AWG 9740' / 2968m
18AWG 6120' / 1865m
19AWG 4860' / 1481m
20AWG 3840' / 1170m
21AWG 3060' / 932m
22AWG 2420' / 737
PC3000RK Wiring Chart
Wire
Gauge
Maximum Run
Length Keypad to
Panel
24AWG 330' / 100m
22AWG 540' / 164m
20AWG 850' / 259m
19AWG 1000' /305m
18AWG 1360' /414m
Smoke detector
power supervision
relay
(DSC RM-1)
11VDC 35 mA
EOLR-1
Smoke detector must be latching type (ESL 445C).
To reset smoke detectors, press and hold [✱][4].
PC2550RK Wiring Chart