8
Control Panel
16 zones
16 fully programmable supervised zones (EOL
resistor)
Programmable for Double EOL resistors
Audible alarm output
Bell output
700 mA, PTC 2.5 Amps, 12 V
DC - commercial
11.0 - 13.8 VDC - residential
Steady or pulsed output
Nonvolatile RAM (Internal Memory)
Does not lose codes or system status on complete AC
and battery failure
Programmable output
Transistor switch sinks 3 A to ground
Programmable for 1 of 35 options
Powerful 1.5 amp regulated power supply
500 mA auxiliary supply, 11.0 - 13.8 V
DC
Separate PTC for battery, auxiliary supply and bell
output
Electronic shut down protection of the Combus
Supervision for loss of AC power, low battery, electronic
shut down of modules
Internal clock locked to AC power frequency or optional
crystal time base
Switched Auxiliary Supply Output
Programmable for 1 of 35 options
11.0 - 13.8 V
DC
300 mA maximum
Battery
12 volt 4 Ah minimum rechargeable gel-cell or sealed
lead-acid battery
Transformer
16.5 VAC, 40 VA
Output Voltage
Typically, with normal AC on and a fully charged battery,
the output voltage will be 13.8 VDC. With AC off and the
battery discharging, the voltage will go below 10 volts and
then battery cutoff will occur preventing further discharge.
Devices that require power from the control panel should
be capable of operation over the voltage range of 10 to 14
V
DC.
Remote Keypad
Four wire (QUAD) hook-up
Alphanumeric liquid crystal display
Built-in piezoelectric buzzer
Full annunciation of zones and system status
Dimensions 5.5” x 4.5” x 1” deep (150 x 114 x 25 mm)
Rated current draw of 55 mA
PC4020 MAIN BOARD
SPECIFICATIONS
Vista de página 7