[06] - [✱]+[4] Door Chime On/Off
This function key provides the user a simple method for turning the Door Chime feature on and off
(See Section
3.4 “[
✱
] Commands, [
✱
] [4] Door chime on/off”)
.
[07] - [✱]+[6]...[4] System Test
This function key provides the user with a simple method for testing the system
(See Section 3.4 “[
✱
]
Commands, [
✱
] [6] User functions”)
. A valid Master Code is required to perform this command.
[08] - [✱]+[1] Bypass Mode
This function key provides the user with a simple method for entering the Bypass Mode. If a access code is
required it must be entered before bypassing can be performed
(See Section 3.4 “[
✱
] Commands, [
✱
] [1] Zone
Bypass”)
.
[09] - [✱]+[2] Trouble Display
This function key provides the user with a simple method for entering the Trouble Display Mode
(See Section 3.4
“[
✱
] Commands, [
✱
]+[2] Trouble display”
).
[10] - [✱]+[3] Alarm Memory
This function key provides the user with a simple method for entering the Alarm Memory Display Mode
(See
Section 3.4 “[
✱
] Commands, [
✱
] [3] Alarm memory”)
.
[11] - [✱]+[5] Programming Access Codes
This function key provides the user with a simple method for programming access codes. After this key is
pressed a valid System Master or Partition Master will have to be entered before the panel will allow
programming to be performed
(See Section 3.4 “[
✱
] Commands, [
✱
] [5] Programming Access Codes”)
.
[12] - [✱]+[6] User Functions
This function key provides the user with a simple method for programming User Functions. After this key is
pressed a valid System Master or Partition Master must be entered before the panel will allow User Functions to
be performed
(See Section 3.4 “[
✱
] Commands, [
✱
] [6] User functions”)
.
[13] - [✱]+[7]+[1] Command Output Option 1
This function key provides the user with a simple method for activating a PGM Output programmed as
Command Output Option 1
(See Section 5.10 “PGM Outputs”)
. By default, after this key is pressed a valid
access code must be entered
(See Section 3.4 “[
✱
] Commands, [
✱
] [7] Command output functions”)
.
[14] - [✱]+[7]+[2] Smoke Detector Reset
This function key provides the user with a simple method for activating a PGM output programmed as either
option [03] Sensor Reset, [04] 2-wire Smoke Support or [20] Command Output option 2.
[15] - General Voice Prompt Help
This feature can only be programmed if both the Escort5580 and the PC5928 Audio Matrix module are being used.
When the function key is pressed, the intercoms will perform a Help page. The user must then press the Page/
Answer button on any intercom station to begin the help session with the Escort.
For more information, please refer to the PC5928 Installation Manual.
[16] - [✱]+[0] Quick Exit
Same as described in Function Keys - Section 3.5.
[17] - [✱]+[1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for adding Stay/Away zones back into the system
(see
Section 3.4 “[
✱
] Commands, [
✱
] [1] Reactivate Stay/Away zones”)
.
[18] Identified Voice Prompt Help
This feature can only be programmed if both the Escort5580 and the PC5928 Audio Matrix module are being used.
When the function key is pressed, the Escort will begin a help session from the intercom station programmed as
closest to the keypad. In order for this option to function, you must program PC5928 Section [802], subsection
[14] “Keypad Port Assignments.” For more information, please refer to the PC5928 Installation Manual.
Note: This function key cannot be programmed for PC55XXZ LED keypads with software version 1.0.
[19] - [✱]+[7]+[3] Command Output 3
[21] - [✱]+[7]+[4] Command Output 4
Function Keys [19] and [21] provide the user with a simple method of activating an output programmed as
Command Output Option 3 or 4.
[22] - Active Camera Monitor Selection
This function key is for use with the PC5108L Downlook Interface/Camera Monitor Module. For instructions on
the function key use, see the PC5108L Installation Manual.
[23] - Bypass Recall
Pressing this function key will recall the last group of bypassed zones. The function key will follow the Code Required
for Bypass option. If the option is enabled, a valid access code with the Bypass attribute enabled must be entered
after the function key is pressed. For instructions on zone bypassing, see the PC5015 Instruction Manual.