DSC Power832 PC5015 Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Sistemas de segurança - controlo de acesso DSC Power832 PC5015. DSC Power832 PC5015 Installation manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Quick Guide

Quick Guideto Power832PC5015For more detailed information, please refer tothe Installation Manual and ProgrammingWorksheets.

Página 2 - Table of Contents

8WiringWiring SABThese bell diagrams indicate how toconnect various bells to thePower832. Take note that the strobeshould be connected to PGM 2 andthi

Página 3 - Features

9WiringWiring SABConnecting A NOVAGUARD 2+TConnecting A NOVAGUARD DeltaEconomy

Página 4 - Installation

Features10 FeaturesTelephonesTelephone ConnectionsThe Power832 is a powerful commu-nications device and it is importantthat you make the correct conne

Página 5

11FeaturesInitial Start UpPower UpInitial Start UpBefore turning on the mains power,make sure that all electrical connec-tions are completed and all d

Página 6 - Wiring Keybus

12Power Upcorrect; and check voltage at the farend. Disconnect furthest item onKeybus and work back measuringvoltage. The panel will provide around550

Página 7 - Wiring 24-hr Devices

13Power UpIf the keypad is showing the orange“Trouble” LED, there is a problemwith the panel. To find more detail onthe problem, press [*][2]. The def

Página 8 - Wiring PIRs

14Power UpCommon Start-Up ProblemsLoss of Clock – Panel needs to havetime and date set. To do this press[*][6][Master Code][1], then entertime/date as

Página 9 - Wiring Fire Detectors

15Features[*] CommandsThe Power832 allows for the access ofinformation and outputs by using [*]commands. These commands arevery similar on all DSC pro

Página 10 - Wiring SAB

Features16 FeaturesPower832 Expansion FlowchartPower832 Expansion Flowchart

Página 11 - Connecting A NOVAGUARD Delta

17FeaturesPower832 Expansion FlowchartPower832 Expansion Flowchart

Página 12 - Telephones

Features36 Features36 Featuresi FeaturesTable of ContentsFeatures ...1Installation ...

Página 13 - Power Up

18[*] Commands[*][5] Programming Access CodesPress [*][5][Master Code]. The keypadwill flash the program light and turnon the zone light for any codes

Página 14

19[*] Commands[*] Commands[*][7] Output Functions[*][7][Access Code] to activate UtilityOutput.[*][7][2] to activate smoke detector orshock sensor res

Página 15

Features20 FeaturesClearing TroublesIf the orange “Trouble” LED is lit,there is trouble on the system. Toview, press [*][2].The trouble condition will

Página 16 - Common Start-Up Problems

21Clearing Troubles[4] Failure to CommunicatePanel unable to send information tocentral station. Check telephoneline, telephone number of CentralStati

Página 17 - [*] Commands

22[*] Commands[1] Further Sub-Menu ofTroublesIf [1] comes ON, push [1] again forspecific trouble present. LED litafter pushing [1] again will indicate

Página 18 - Power832 Expansion Flowchart

23FeaturesModule GuideThe following modules can be usedwith the PC5015.Keypads (Max. of 8 per system)PC5508TZ – 8 Zone LED keypadPC5532TZ – 32 Zone LE

Página 19

Features24 FeaturesDefault Settings001 Zone DefinitionsZone 1 01 Entry/ExitZone 2 25 InstantZone 3 03 InstantZone 4 03 InstantZone 5 03 InteriorZone 6

Página 20

25FeaturesBasic ProgrammingNow let’s look at how to change someof the default settings listed on theprevious page. If you are using thePower832 as a “

Página 21

26Basic ProgrammingOnce you press [#] to exit section005, the keypad will again display“Enter Section” followed by threedashes.If you want to make cha

Página 22 - Clearing Troubles

27Basic ProgrammingTo toggle options “ON” or “OFF”press the corresponding number onthe keypad. Press [2] and the dash isreplaced by the number, indica

Página 23

1FeaturesFeatures• 8 on-board zones• Expandable to 32 zones via 8zone modules or wireless module• Supports up to 8 keypads• LED and LCD versions avail

Página 24

28Basic ProgrammingProgramming Examples:Using a LCD keypadBasic Programming

Página 25 - Module Guide

29FeaturesTranslationThe Language Barrier(01) Delay 1 =Final Exit 1(02) Delay 2 =Final Exit 2(03) Instant =Normal Zone(05) Interior Stay/Away = (Part

Página 26 - Default Settings

Features30 FeaturesUsingUsing the Big Booksthe Big BooksHow to use the Installation Manualand Programming Worksheets in-cluded with this panel:The Pro

Página 27 - Basic Programming

31Using the Big BooksSection 2 refers to wiring the controlpanel, including a description of themain panel terminal strip, the connec-tion and operati

Página 28

32Using the Big BooksFor example, you may not be surewhat “TLM Enable” means in pro-gramming section 15. Beside theoption number is a reference number

Página 29

33FeaturesTechnical Support:01482 322228/329911

Página 30

Unit C51Winfrith Technology CentreWinfrith NewburghDorchesterDT2 8DHTelephone01305 851700Fax01305 851660Email: [email protected]: www.dscuk.co

Página 31 - Translation

Features2 FeaturesInstallationInstalling the Power832Control PanelThe following steps should be carriedout in the order described below. Thiswill help

Página 32

3Installation5. Connect all modules on theKeybus using STAR or DAISYchain, red to red, black to black,yellow to yellow and green togreen.6. Connect al

Página 33 - Using the Big Books

Features4 FeaturesWiringWiring KeybusThe Keybus wiring is the most impor-tant part of the installation process ofthe Power832 and its associatedmodule

Página 34

5WiringWiring 24-hr DevicesThe diagram below shows how toconnect door contacts, break glassdetectors and panic attack buttons tothe Power832 using dou

Página 35 - 01482 322228/329911

6WiringWiring PIRsAlthough zones can be be wired asdouble end of line (DEOL), single endof line (SEOL) or normally closed, werecommend DEOL for all in

Página 36

7WiringWiring Fire DetectorsThe diagram below shows how smokedetectors should be connected to thePower832 control panel.Always check the manufacturer’

Comentários a estes Manuais

Sem comentários