22
3 All other non-alarm reporting codes must be set up to send an extended 2nd round. The 1st digit of the
reporting code is used to identify the event while the 2nd or extended digit is used to associate the event with a
particular item (for example, a reporting code of E3 means restore zone 3; E for restore and 3 for zone 3).
4 The following is a list of 1st digit identifiers that should be used with the Radionics format:
Restorals “E” Example “E3” = Restore Zone 3
Openings “B” Example “B2” = Opening by User 2
Closings “C” Example “C4” = Closing by User 4
Troubles “F” Example “F5” = Trouble from Source 5
Misc “D” Example “D1” = Partial Closing
Sescoa Super Speed Format
The following guidelines are provided to help in configuring the PC2525 for use with the Sescoa Super Speed
format.
1 The account code must be four decimal digits in length and in the range of 0001 to 3374.
2 The reporting codes must be 2 digits in length and programmed as follows.
Alarms Zones 1-8 Section [34] A1 to A8
Restorals Zones 1-8 Section [35] A1 to A8
All Opening Codes Section [37] BA
All Closing Codes Section [36] CA
Partial Closing Section [36] C1
Low Battery Section [39] E1
Battery Restorals Section [40] E1
AC Failure Section[39] E1
AC Restoral Section [40] E1
Bell Trouble Section [39] F1
Bell Restoral Section [40] F1
Troubles Sections [39] & [40] AA
Misc. Alarms Section [38] (A1 to 99)
Test Code Section [39] 1C or DC
System Test Code Section [39] CC
After Alarm Code Section [37] B1
Auto-Arm Cancel Code Section [36] C8
TLM Restoral Code Section [40] EE
[45] Communicator Call Direction
This section requires four single digit entries using the numbers 0 to 3 only. This section defines how the
communicator will call the telephone numbers programmed in Sections [30] and [32] to report the following
events:
Zone Alarms and Restorals Priority Alarms and Restorals
Access Codes Openings and Closings Maintenance Alarms and Restorals
Enter ONE digit from the list below for each of the above categories.
0 Disables the function (no transmission for the group)
1 Call First phone number and back-up to the Second phone number when Section [46] Zone Light 4 is OFF
and the panel has made 8 unsuccessful tries on the First phone number.
2 Call the Second phone number only
3 Always call both phone numbers
If the [#] key is pressed during data entry, you will be returned to the installer’s Programming Mode and data for
this section will NOT be saved.