P R O G R A M D E S C R I P T I O N S
35
For commercial applications Bell Squawk on Entry Delay may be enabled. The panel will squawk the
alarm output once every second until the entry delay expires or the system is disarmed. This feature must
not be used with 2 partitions.
Since two Delay zones are programmable, and therefore two different Entry Delays, when the panel is
armed it will use the Entry Delay for the first Delay zone violated.
If the Bell Squawk During Auto Arm option is enabled, the bell will squawk while the system is auto-
arming in order to notify anyone on the premises that the system is being armed.
If Exit Delay Termination
is enabled the panel will monitor the Delay zones during exit delay. If a Delay
type zone is violated then secured during the exit delay, the exit delay will be terminated and the panel
will be armed immediately.
To prevent false alarms, use the built-in feature Audible Exit Fault. If a delay type zone is violated within
4 seconds after the exit delay has expired, the panel will sound the entry delay warning through the
keypad and siren alerting the customer that an improper exit was made. If the panel is disarmed within
the entry delay no signal is sent. If not, the panel will continue to sound the alarm and send a signal to
central station. This feature can be disabled in Section [013] Option [6].
Bell Squawk During Auto Arm................................ Section [014], Option [2]
Bell Squawk on Exit Delay ..................................... Section [014], Option [3]
Bell Squawk on Entry Delay................................... Section [014], Option [4]
Audible Exit Delay ................................................... Section [014], Option [6]
Audible Exit Fault .................................................... Section [013], Option [6]
Exit Delay Termination ............................................ Section [014], Option [7]
5.16 Event Buffer
The panel will store the last 128 events that have occurred on the system. Each event will contain the
time, date, partition and the event itself along with the zone number, user code number or any other
information pertaining to the event.
If the Event Buffer Follows Swinger Shutdown feature is enabled the event buffer will not store events
after the swinger shutdown level has been reached. This will prevent the panel from overwriting the entire
buffer if a problem exists.
(See Section 5.17 “Swinger Shutdown”.)
The event buffer can be viewed three different ways. It can be viewed through an LCD keypad, printed
on-site using the PC5400 printer module
(See Section 5.29 “On-Site Printer”)
or it can be uploaded
through the DLS software.
5.16.1 Viewing the Event Buffer through the LCD Keypad
The following is the procedure for viewing the event buffer through the LCD keypad:
Step 1 - Enter [✱] [6] [Master Code] Step 2 - Select ‘View Event Buffer’
The keypad will display the Event Number, Partition, Time and Date of the event in question. Use the [✱]
key to toggle between this information and the event itself. Use the arrow keys (<>) to scroll through the
events in the buffer.
When you have finished viewing the event buffer press the [#] key to exit.
Event Buffer Follows Swinger Shutdown............... Section [013], Option [7]
5.17 Swinger Shutdown
The swinger shutdown feature is designed to prevent a runaway communicator from tying up the central
station. Different limits can be programmed for Zone Alarms, Zone Tampers
and Maintenance
signals.
After the panel has communicated the programmed number of transmissions for an event it will no longer
report that event until the swinger shutdown is reset.
For example, the swinger shutdown limit for Zone Alarms is set to [003]. The panel will not send more than
3 alarm signals for each zone with a swinger attribute until the swinger shutdown is reset.
The Bell output will not be activated for alarms on zones that have exceeded the limit of alarms set in the
Swinger Shutdown counter.
Swinger Shutdown
will be reset when the panel is armed or every day at midnight. Once reset, the panel
will again communicate normally.
Swinger Shutdown Limit (Alarms/Tampers/Maintenance) Section [370]
5.18 Transmission Delay
If Transmission Delay is selected for a zone the panel will delay reporting the alarm for the number of seconds
programmed for Transmission Delay Time. If the panel is disarmed before the delay time expires the panel will
not report the alarm to central station. If the panel is not disarmed in time the panel will communicate normally.
This is a global feature - the transmission delay time will be the same on both partitions.
Transmission Delay Enable .................................... Sections [101] to [132], Option [7]
Transmission Delay Time ....................................... Section [370]