PowerSeries - PC1616/PC1832/PC1864
14
Section [017] Fifth System Option Code
Section [018] Sixth System Option Code
Section [019] Seventh System Option Code
For Future Use
[5] ON: keypad backlighting enabled. OFF: keypad backlighting disabled.
[6] ON: the system temporarily enables the Keypad Blanking feature if an AC failure is detected (to preserve the back up battery).
OFF: the system will operate as normal.
[7] ON: the keypad turns ON the Bypass light if zones are bypassed while the system is armed. OFF: the Bypass light turns OFF when
the system is armed.
[8] ON: the system supervises keypad tampers. OFF: the system does not supervise keypad tampers.
Option Description
[1] ON: the system does NOT associate wireless keys to user codes. OFF: the system will assign user code 17 to wireless key #01,
user code 18 to wireless key #02 etc. If the wireless key is used to arm or disarm, the system will report the Opening or Closing for
the associated User Code.
[2] ON: the system generates an RF Jam trouble condition if the condition is present for 5 minutes. OFF: the system generates the
trouble condition after 30 seconds.
[3] ON: the keypads beep if an RF Jam trouble is detected. OFF: the trouble is not annunciated via the keypad buzzer.
[4] ON: the Double Hit feature will be enabled. Two violations from the same zone within the Cross Zone Timer will be considered a
valid Police Code or Cross Zone event. The system will report the event and log it to the event buffer.
OFF: two alarms from the same zone is not a valid Police Code or Cross Zone event.
[5] ON: the system logs and communicates a Late-To-Close event when it auto-arms at the programmed time (not if auto arming was
caused by the No-Activity Arming feature). OFF: the system does not transmit or log a Late-To-Close event.
[6] ON: enables the Daylight Savings automatic clock adjustment feature. OFF: the system does not automatically adjust the clock for
Daylight Savings.
[7] For Future Use
[8] ON: the system only squawks the bell output when the system is armed in the Away mode. OFF: the system squawks the siren
when the system is armed in any mode. (See Section [14]).
Option Description
[1] ON: the system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during the
programmed time. OFF the system always transmits a Test Transmission reporting code as programmed.
[2]-[4] For Future Use
[5] ON: the keypad buzzer follows the bell output for all alarms. OFF: the system only activates the bell output for all alarms.
[6] ON: When an alarm is detected on a zone (with the Cross Zone attribute enabled), a timer is started. The alarm is not transmitted and
the bell output is not activated unless a second cross zone enabled zone is violated before the Cross Zone timer times out. OFF: the
system reports all alarms normally and logs and transmits a Police Code reporting code if a second zone alarm is detected during the
armed period.
[7] ON: the system restarts the Exit Delay (one time) if a Delay zone is violated and restored during the exit delay time. OFF: exit
delay does not restart.
[8] ON: the system activates the trouble beeps when an AC trouble is detected. OFF: the system does not annunciate AC troubles
using the keypad buzzer.