P R O G R A M D E S C R I P T I O N S
31
[11] System Tamper
The PGM Output will activate when any Tamper condition is present and will deactivate when
all Tamper conditions are cleared.
[12] TLM and Alarm
The PGM Output will activate when a telephone line fault condition is present AND an alarm
occurs. The PGM Output will remain active until an access code is entered. The output will activate for both audible
and silent alarms if a TLM trouble is present.
This output will activate for all audible and silent alarms except Duress.
[13] Kissoff The PGM Output will activate for two seconds after the panel receives the kissoff from the central station.
[14] Ground Start
(Shall not be enabled on UL Listed systems)
The PGM Output will activate for two seconds
before the panel attempts to dial to obtain dial tone on Ground Start telephone equipment. Two second pauses should
be inserted at the beginning of the phone number when using this option.
[15] Remote Operation (DLS-1 Support)
This output can be activated and deactivated remotely using DLS software.
[16] LINKS1000 Support (PGM1 Only) The PGM output will be used as a data wire to communicate phone
number information for the LINKS1000 cellular unit.
[17] Away Armed The PGM will activate when the system is armed with the Stay/Away zones activated.
[18] Stay Armed The PGM will activate when the system is armed with the Stay/Away zones bypassed.
[19] [] [7] [1] Command Output Option #1
[20] [] [7] [2] Command Output Option #2 Press [
]
[7] [2] [Access Code, if required] to activate any output
programmed as one of PGM output option [03] or [20].
Traditionally, [] [7] [2] has been reserved for resetting smoke detectors. Smoke detectors should now be
programmed as output [03] Sensor Reset.
Only ONE of options [03] Sensor Reset, [04] 2-Wire Smoke and [20] [
] [7] [2] Command Output Option
#2 may be programmed on the same system.
[21] [] [7] [3] Command Output Option #3
[22] [
] [7] [4] Command Output Option #4 These outputs are user-initiated by entering [] [7] [1-4] at any
keypad. When any output is activated, three acknowledgment beeps are heard.
[23] Silent 24 Hour (PGM2 Only) A Panic button may be placed on the PGM2 terminal for use as a silent 24
hour Panic. The keypad will not indicate the alarm in any way and the Bell will remain silent but the PGM2 Alarm
reporting code will be sent to the central station. PGM output option [23] will not activate other programmable
outputs of any kind. This input does not follow Swinger Shutdown.
[24] Audible 24 Hour (PGM2 Only) A Panic button may be placed on the PGM2 Terminal for use as an Audible
24 Hour Panic. When the button is pressed, LCD keypads will indicate System in Alarm, the bell will sound until
the Bell Cut-off expires, and the PGM2 Alarm reporting code will be sent to the central station. PGM output option
[24] will not activate other programmable outputs except for outputs programmed as [01]. This input does not
follow Swinger Shutdown.
Main Board PGM Outputs ..................................... Section [009]
PC5208 PGM Output Options ............................... Section [010]
PC5204 PGM Output Options ............................... Section [011]
5.10.2 PGM Output Attributes
In addition to programming the output type, you must also program the PGM output attributes for each output.
PGM output options [09] System Trouble and [10] Latched System Event have their own unique set of
attributes listed below the description of each output type.
PGM output options [01], [03], [05]-[08], [11]-[24] have the following attributes:
Attribute ON OFF
[1] Partition 1 controls event Partition 1 Does Not
[2] Partition 2 controls event Partition 2 Does Not
[3] True Output Inverted Output
The output energizes when activated The output will de-energize when activated.
(except for Option [03] Sensor Reset).
[4] 5 Second Pulse Output ON/OFF
The output will activate once for five The output will turn ON and OFF when initiated by
seconds when initiated by the user. the user
(only applicable to options [19] to [22]).
[5] Access Code Req. No code Req.
The output requires a code for activation. No code required.
(only applicable to keypad-activated outputs)
PGM attributes return to their default settings when you change PGM output options. Please see the
programming worksheets for a list of the default settings for each PGM output type.
Care should be taken in selecting the normal and active states of each PGM output to ensure that an
undesirable output state does not occur after a loss and restore of AC power.