Access Code Programming
In addition to the Master Access Code, you can program up to 39 additional User Access codes.
Press , plus your Master Access Code. The Program or System indicator will begin to flash,
and the Armed ( ) indicator will tur n on.
Enter the 2-digit number to be programmed (i.e., 06 for user access code 6; enter 40 for the Master
Access Code).
When using the PK5500, use the keys to find the specific code and press to select. Enter
the new 4 -digit access code, or press to erase it. When programming is complete, enter another
2-digit code to program or press to exit.
Access Codes
[][5][Master Code] (when disarmed)
The [][5] User’s Programming command is used to program additional access codes.
Master Code (Access Code 40) - Your initial Master Code will be supplied to you by your installer;
however, you should change it.
• To change your Master Code, enter [][5][current Master Code] [40][new Master Code].
• Press [#] to return to the Ready state. Keep your Master Code in a safe location. If you lose your
Master Code, it can be reset by your installer.
Supervisor Codes - These codes are always valid when entering the User Code Program-
ming section. However, these codes can only program additional codes which have equal or lesser
attributes. Once programmed, the Supervisor Codes receive the Master Code’s attributes. These
attributes are changeable. Any User Code can be made a supervisor code by enabling User Code
Attribute 1 (please see below for details).
Duress Codes - Duress codes are standard User Codes that will transmit the Duress Reporting Code
whenever the code is entered to perform any function on the system. Any User Code can be made a
Duress Code by enabling User Code Attribute 2 (please see below for details).
NOTE: Duress codes are not valid when entering [][5], [][6] or [][8] sections.
NOTE: Access codes cannot be programmed as a duplicate or as a “Code +1”.
User Code Attributes
1. The default attributes of a new code will be the attributes of the code used to enter
whether it is a new code or an existing code being programmed.
2. System Master (Code 40) has Attributes 3-4 ON by default.
NOTE: Master Code attributes are not changeable.
Inherent Attributes (all codes except installer and maintenance)
Arm/Disarm - Any Access Code will be valid for arming and disarming the system.
Command Outputs ([][7][1], [][7][2], [][7][3], and [][7][4]) - If these outputs requir e Access
Code entry, any Access Code will be valid for performing the [][7][1-4][Access Code] functions on the
system.
Programmable Attributes ([][5][Master/Supervisor Code][9][Code])
1. Supervisor Code
2. Duress Code
3. Zone Bypassing Enabled
4. Remote Access
5. For Future Use
6. For Future Use
7. For Future Use
8. One T ime Use Code
NOTE: Remote arming or downloading should not be performed in UL listed installations.